Operative Techniques in Thoracic and Cardiovascular Surgery: A Comparative Atlas
Volume 11, Issue 3 , Pages 200-206 , Autumn 2006

Technique of Mechanical Pulmonary Valve Replacement

  • John M. Stulak, MD
  • ,
  • Joseph A. Dearani, MD

      Affiliations

    • Corresponding Author InformationAddress reprint requests to: Joseph A. Dearani, MD, Division of Cardiovascular Surgery, Mayo Clinic College of Medicine, 200 First Street SW, Rochester, MN 55905.

References 

  1. Bermudez CA, Dearani JA, Puga FJ, et al. Late results of the peel operation for replacement of failing extracardiac conduits. Ann Thorac Surg. 2004;77(3):881–887
  2. Dearani JA, Danielson GK, Puga FJ, et al. Late follow-up of 1095 patients undergoing operation for complex congenital heart disease utilizing pulmonary ventricle to pulmonary artery conduits. Ann Thorac Surg. 2003;75(2):399–410
  3. Ilbawi MN, Lockhart CG, Idriss FS, et al. Experience with St. Jude Medical valve prosthesis in children: a word of caution regarding right-sided placement. J Thorac Cardiovasc Surg. 1987;93:73–79
  4. Kiyota Y, Shiroyama T, Akamatsu T, et al. In vitro closing behavior of the St. Jude Medical heart valve in the pulmonary position: valve incompetence originating from the prosthesis itself. J Thorac Cardiovasc Surg. 1992;104:779–785
  5. Burger W, Kneissl GD, Hartmann A, et al. Successful thrombolysis after prosthetic pulmonary valve obstruction under aspirin monotherapy. Ann Thorac Surg. 1997;64:255–258
  6. Nurozler F, Bradley S. St. Jude Medical valve in pulmonary position: anticoagulation and thrombosis. Asian Cardiovasc Thorac Ann. 2002;10:181–183
  7. Pass HI, Sade RM, Crawford FA, et al. Cardiac valve prostheses in children without anticoagulation. J Thorac Cardiovasc Surg. 1984;87:832–835
  8. Rosti L, Murzi B, Colli AM, et al. Mechanical valves in the pulmonary position: a reappraisal. J Thorac Cardiovasc Surg. 1998;115(5):1074–1079
  9. Kawachi Y, Masuda M, Tominaga R, et al. Comparative study between St. Jude Medical and bioprosthetic valves in the right side of the heart. Jpn Circ J. 1991;55:553–562
  10. Haas F, Schreiber C, Horer J, et al. Is there a role for mechanical valved conduits in the pulmonary position?. Ann Thorac Surg. 2005;79(5):1662–1667
  11. Korfer R, Kortke H. ESCAT early self controlled anticoagulation trial. Ann Thorac Surg. 2001;72:44–48

 Presented as part of the Controversies in Cardiothoracic Surgery Session of the 86th Annual Meeting of the American Association for Thoracic Surgery, Philadelphia, Pennsylvania, April 29–May 3, 2006.

PII: S1522-2942(06)00082-1

doi: 10.1053/j.optechstcvs.2006.05.003

Operative Techniques in Thoracic and Cardiovascular Surgery: A Comparative Atlas
Volume 11, Issue 3 , Pages 200-206 , Autumn 2006